Enerdrive ePOWER DC2DC 12V 40A+ Battery Charger - Two DC Inputs 10.5-32V (e.g. Engine Charging and Solar) 12V 40A+ Output (EN3DC40+)
Enerdrive ePOWER DC2DC 12V 40A+ Battery Charger - Two DC Inputs 10.5-32V (e.g. Engine Charging and Solar) 12V 40A+ Output (EN3DC40+)
- $629.00
-
$489.00
- OR -
Australia's Best Price on Enerdrive DC 2 DC ePOWER 40A+ DC to DC Battery Charger (EN3DC40+)
Two DC Inputs (e.g. Engine Charging and Solar) 40-50A 12V Output
CHARGES 12V BATTERY SYSTEMS (10.5 – 16VDC / 21 – 32VDC Vehicle INPUT VOLTAGE)
Charges Flooded, AGM, GEL, Lithium Batteries + Custom Program
MPPT Solar Controller (14.5-45VOC - ≤ 23V input, 500W (600W allowable) ≥37.5V-45V input, 750W (800W allowable))
Australia Wide Shipping To Most Areas in Queensland, Victoria, NT, South and Western Australia
overview
Enerdrive DC 2 DC ePOWER 40A+ DC to DC Battery Charger (EN3DC40+)
Two DC Inputs (e.g. Engine Charging and Solar) 10.5-32VDC Input - 40A+ 12V Output
Charges Flooded, AGM, GEL, Lithium and Program Batteries
MPPT Solar Controller (Input 14.5-45VOC | ≤ 23V input, 500W (600W allowable) ≥37.5V-45V input, 750W (800W allowable))
Specifically designed for use in Marine-Boat-Caravan-Camptrailer-Motorhome-RV
* Freight Australia Wide Australia Wide Shipping (*Excludes remote areas and PO Boxes)
Designed to meet the rugged demands of Australian conditions and delivering multiple source charging for DC systems. The Enerdrive ePOWER DC2DC+ Battery Charger is a fully automatic multistage, multi input battery charger with the ability to charge from either an alternator linked to a battery; or via solar power with the in built Maximum Power Point Tracking (MPPT) Solar Controller.
- Two totally independent DC Inputs for both engine and solar regulation charging one house battery bank output
- DC M6 screw terminals that will allow for large battery cable connection between all sources
- A dedicated Maximum Power Point (MPPT) solar regulator
- The same battery algorithms as included in our AC mains ePOWER battery charger including a specific lithium charging profile
- 40A output up to 40+°C with thermo controlled fan cooling
- Fully programmable LCD display to show which source is charging the battery along with charger status, voltage and amperage
- Temperature sensor included in charger for more accurate battery charging
The Enerdrive ePOWER DC2DC Battery Charger is a fully automatic multistage, multi input battery charger with the ability to charge from either an alternator linked to a battery; or via solar power with the in built Maximum Power Point Tracking (MPPT) Solar Controller. With two inputs available, the house battery will be charged from either the engine while underway, or via the solar panels when stationary. The process to choose either engine or solar is fully automatic and both functions are controlled from within the unit itself without the need for external relays.
During normal operation the ePOWER DC2DC Battery Charger will do a full charge cycle to float stage on the house battery bank with ability to choose either GEL, AGM, Flooded, Custom Programmable or Lithium. Once float stage is reached the charger transitions to a power supply mode to support any on-board DC loads.
Multistage Charging Process
The ePOWER DC2DC+ Battery Charger is a fully automatic, set and forget charger. It is designed to quickly and accurately recharge your deep cycle batteries utilising charger algorithms that help to maximise the life of your specialised deep cycle batteries.
The ePOWER DC2DC+ Battery Charger features multistage smart charging technology that enables the charger to be connected to your battery banks permanently. With the input of multiple sources, you can be assured of charging your batteries whenever underway; or when the sun is shining on your solar array.
As dictated by battery manufacturer’s recommendations, deep cycle batteries require a multistage charge sequence for perfect, fast and accurate charging. The Enerdrive ePOWER DC2DC smart charger delivers three primary charge stages.
Stage 1 – Bulk or Boost charge; The battery is charged at full rated output current of the charger until the battery reaches its final charging voltage, known as its absorption voltage. In this step, around 80% of the battery is recovered as fast as possible.
Stage 2 – Absorption Charge; With the charger voltage held steady, the remaining 20% is replaced with the charger allowing the current to taper off as the battery approaches full charge.
Stage 3 – Float; Finally, in the float stage the charger voltage is lowered and held at a constant and safe predetermined level. This prevents the battery from being overcharged, yet allows the charger to supply enough current to make up for the self-discharge losses of the battery, while supporting any additional loads connected to the battery (such as DC lighting and refrigerators). This stage allows for the charger to be used as a DC power supply.
Smart Charging Feature
The ePOWER DC2DC+ Battery Charger will regulate its output based on the loads connected to your battery banks. This function is important to maintain the life of your battery banks as some battery chargers mistake loads for discharge and continue to keep the batteries in the bulk or absorption stage for extended periods of time, which will damage the battery bank. The ePOWER DC2DC+ Battery Charger has two methods of load based regulation to ensure your battery charger transitions to float when it should do so.
Options:
- EN3TEMP - Replacement Temperature Sensor to Suit ePOWER Chargers
- DC40 Install Kit, includes (while stock lasts)
- 2 x Midi Fuse Holders,
- 1 x 70A Vehicle Input Fuse,
- 1 x 60A Battery Charge Output Fuse
- 1 x 2.4A Twin USB Socket
DC Install Kit
Downloads:
- DC2DC+ ePOWER Brochure
- DC2DC+ ePOWER Charger User Manual
- DC2DC+ ePOWER In Vehicle/Marine Wiring Diagram
- DC2DC+ ePOWER In Towed Vehicle Wiring Diagram
Maximising your Solar Harvest using the DC2DC+
The Solar Input on the DC2DC+ unit has a maximum rated INPUT current of 30amps. This means it is optimised for using higher voltage ‘grid’ type modules for best output performance. The maximum achievable output using standard 20Voc solar modules will be approx 35amps @ 14.4Vdc
Panel Array |
Rated Wattage & Volts |
Open Circuit rating |
Estimated DC Amps Output (## See Below) |
---|---|---|---|
1 |
150watt @ 20Voc |
150watts |
10 |
1 |
200watt @ 43Voc |
200watts |
13 |
2 |
150watt @ 20Voc |
300watts |
21 |
2 |
200watt @ 43Voc |
400watts |
27 |
3 |
150watt @ 20Voc |
450watts |
31 |
3 |
200watt @ 43Voc |
600watts |
42 |
4 |
150watt @ 20Voc |
600watts |
35* |
4 |
200watt @ 43Voc |
800watts |
47** |
5 |
150watt @ 20Voc |
1000watts |
Not Recommended |
5 |
200watt @ 43Voc |
1000watts |
Not Recommended |
* Maximum achievable output on the DC2DC+ unit when using 20Voc Solar Panels will be the approx 35amps.
** Maximum achievable output on the DC2DC+ unit when using 43Voc Solar Panels will be the approx 47amps.
## IMPORTANT NOTE: Estimated Amps Output is quoted based upon PERFECT Solar conditions including Sun Angle, Panel Mounting angle and Orientation to the sun. It needs to be noted that panel performance alters dramatically between Summer and Winter periods and actual performance may be impossible to predict.
specification
Output Rating | |
---|---|
Output Voltage | 12V Nominal (8.0V min) |
Output Current (Maximum) | 40A ~ 50A |
Output Power | 775W |
Charger DC Output (CH1): |
|
---|---|
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program |
Charger Voltage Range | 13.8V – 15.5V |
Float Voltage Range | 13.0V – 13.8V |
Charger Current (User Selectable) | 5/10/15/20/25/30/35/40/45/50A (default 40A) |
Equalize Voltage (Flooded Battery) | 15.5V |
Equalize Charging Current | 10% of Bulk Current Setting |
Charging Control | 2 stage / 3 stage selectable (Default 3 stage) |
DC Output Bank | Single |
Current draw from CH1 when in use | = < 50mA |
Battery Temperature Setting | Low/ Normal/ High (Battery Temperature Sensor Standard) |
Efficiency | 95% |
INPUT Rating (CH2 – MPPT Solar) |
|
---|---|
Input Voltage | 14.5 – 45VOC |
Maximum Input | ≤ 23V input, 500W (600W allowable) ≥37.5V-45V input, 750W (800W allowable) |
INPUT Rating (CH3 – Start/Alternator) |
|
---|---|
Input Voltage | 10.5 – 16VDC / 21 – 32VDC |
Note: Specifications subject to change without notice. |
---|
Circuit Protection (Circuit Breakers and Fuses) – Choosing an Amperage Rating – Generally, circuit protection devices are installed to protect the wiring from overheating during overloads or faults. The simplest approach for selecting a circuit protection device rating is to choose an amperage rating that is equal to or less than the current rating, ampacity of the wire. If the wire ampacity is significantly greater than the load current, as might be with small loads or with wiring of increased size to reduce voltage drop, then a range of circuit protection values between the load requirement and the wire ampacity may be acceptable. Larger ampacity values reduce the probability of nuisance failures and reduce fuse heating; smaller ampacity values provide more conservative protection for the wiring.
In some cases, a product manufacturer may recommend that a specific fuse or circuit breaker size should be used with the product. If that is the case, the wire to the product should be selected so that the wire ampacity exceeds the recommended rating, which will protect both the product and the wiring.
*Excerpt from Blue Sea Systems https://www.bluesea.com/support/articles/Circuit_Protection/98/DC_Circuit_Protection
We recommend Enerdrive waterproof surface mount re-settable circuit breakers for performance and value;
- 25A Surface Mount Resettable Waterproof Circuit Breaker
- 30A Surface Mount Resettable Waterproof Circuit Breaker
- 40A Surface Mount Resettable Waterproof Circuit Breaker
- 50A Surface Mount Resettable Waterproof Circuit Breaker
- 60A Surface Mount Resettable Waterproof Circuit Breaker
- 70A Surface Mount Resettable Waterproof Circuit Breaker
- 80A Surface Mount Resettable Waterproof Circuit Breaker
- 100A Surface Mount Resettable Waterproof Circuit Breaker